Technical
Information |
|
 |
Technical ( 8 of 12 )  |
BRAZING
Facilities are available for brazing components, in vacuum, or reducing
atmosphere, up to 250mm diameter × 300mm long. The braze material normally
employed will be Silver/Copper eutectic. This preferred material produces
a high seal strength at low cost. For applications where higher operating
temperatures or other design constraints are involved, Gold/Copper,
Gold/Nickel or Copper braze materials are employed, the latter braze
material having a liquidus point of approximately 1100°C. |
 |
|
mbar |
VAPOUR PRESSURE OF BRAZE ALLOYS |
1 x 10-9 |
 |
1 x 10-8 |
1 x 10-7 |
1 x 10-6 |
1 x 10-5 |
1 x 10-4 |
1 x 10-3 |
1 x 10-2 |
600 |
700 |
800 |
900 |
1000 |
1100 |
1200 |
|
Temperature °C |
 |
 |
|